引用本文:董义华,孙同景,徐丙垠.基于三次样条插值理论的电子式互感器数据同步[J].电力自动化设备,2012,32(5):
DONG Yihua,SUN Tongjing,XU Bingyin.Data synchronization based on cubic spline interpolation for electronic instrument transformers[J].Electric Power Automation Equipment,2012,32(5):
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 5464次   下载 70  
基于三次样条插值理论的电子式互感器数据同步
董义华1, 孙同景1, 徐丙垠2,3
1.山东大学 控制科学与工程学院,山东 济南 250061;2.山东理工大学 电气技术研究所,山东 淄博 255049;3.科汇电气自动化公司,山东 淄博 255087
摘要:
介绍了电子式互感器的数据同步问题,并对线性插值和二次插值的同步算法进行分析,指出线性插值算法在谐波次数高的情况下误差过大和二次插值算法在低采样频率下误差改进不明显。提出了基于三次样条插值理论的同步算法,并进行了误差的理论分析和数值仿真计算。理论误差分析表明,该算法相比较于线性插值算法和二次插值算法,误差值至少降低2个数量级;数字仿真验证显示,每周期48点采样时,稳态采样值最大误差约为输入电流最大幅值的0.000 38 %,暂态采样值最大误差约为输入电流最大幅值的0.005 %,采样值误差均降低2个数量级以上。在包含基频量和高次谐波电量的二次设备中,该算法可降低各采样点的相对误差,方法误差精度均可满足IEC60044标准规定的电子式互感器的误差要求,即稳态测量精度0.2级和暂态分量最大瞬时值误差小于 ± 1 %。
关键词:  电子式互感器  同步  插值  误差分析  IEC60044  仿真
DOI:
分类号:
基金项目:
Data synchronization based on cubic spline interpolation for electronic instrument transformers
DONG Yihua1, SUN Tongjing1, XU Bingyin2,3
1.School of Control Science and Engineering,Shandong University,Ji’nan 250061,China;2.Shandong University of Technology,Zibo 255049,China;3.Kehui Power Automation Co.,Zibo 255087,China
Abstract:
The synchronization of electronic instrument transformer data is introduced and the synchronization algorithms based on linear interpolation and quadratic interpolation are analyzed,which shows that,the linear interpolation algorithm has large error when the order of harmonic is high and the quadratic interpolation algorithm has no obvious improvement when the sampling frequency is low. The synchronization algorithm based on cubic spline interpolation is presented with simulation and error analysis,which shows that its error is lower by at least two orders than that of linear interpolation algorithm or quadratic interpolation algorithm. Digital simulation shows that,the maximum steady-state sampling error is about 0.000 38% and the transient sampling error is about 0.005% of the maximum input current amplitude when the sampling frequency is 48 points per period. The proposed algorithm has lower relative error,suitable for measuring the harmonics and fundamental of secondary devices,and higher accuracy,meeting the requirements for electronic instrument transformer errors stipulated in IEC60044 standard,i.e. the steady-state accuracy class 0.2 and the maximum instantaneous transient component within ±1%.
Key words:  electronic instrument transformer  synchronization  interpolation  error analysis  IEC60044  computer simulation

用微信扫一扫

用微信扫一扫