引用本文:何天雨,石睿智,张泽,耿亚明,王锐,臧海祥.含统一潮流控制器的拟线性化动态最优潮流[J].电力自动化设备,2018,(11):
HE Tianyu,SHI Ruizhi,ZHANG Ze,GENG Yaming,WANG Rui,ZANG Haixiang.Quasi-linearized dynamic optimal power flow with unified power flow controller[J].Electric Power Automation Equipment,2018,(11):
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 3686次   下载 1704  
含统一潮流控制器的拟线性化动态最优潮流
何天雨1, 石睿智1, 张泽1, 耿亚明2, 王锐1, 臧海祥3
1.国网江苏省电力有限公司泰州供电公司,江苏 泰州225300;2.国网江苏省电力有限公司检修分公司泰州运维站,江苏 泰州225300;3.河海大学 能源与电气学院,江苏 南京211100
摘要:
统一潮流控制器(UPFC)具有强大的潮流控制能力,但是目前工程中的控制策略仅停留在控制站层面;含UPFC的动态最优潮流计算可以有效提高电网的安全性和经济性,但是其计算效率低、收敛性差,难以满足电网实时性要求。基于此,通过解耦、代换、热启动和迭代更新4个步骤,提出对初值不敏感的线性化动态最优潮流模型,并研究拟线性化的UPFC模型,最终建立含UPFC的拟线性化动态最优潮流模型。基于等值原理,从地区电网数据中提取南京西环网117节点等值系统,采用简化原对偶内点法对其进行求解测试,算例结果表明所建模型具有较高的计算效率和计算精度。
关键词:  统一潮流控制器  动态最优潮流  拟线性化  等值系统
DOI:10.16081/j.issn.1006-6047.2018.11.013
分类号:TM711
基金项目:中国博士后科学基金资助项目(2015M571653)
Quasi-linearized dynamic optimal power flow with unified power flow controller
HE Tianyu1, SHI Ruizhi1, ZHANG Ze1, GENG Yaming2, WANG Rui1, ZANG Haixiang3
1.State Grid Jiangsu Electric Power Co.,Ltd. Taizhou Power Supply Company, Taizhou 225300, China;2.State Grid Jiangsu Electric Power Co.,Ltd. Maintenance Branch Company Taizhou Operation and Maintenance Station, Taizhou 225300, China;3.College of Energy and Electrical Engineering, Hohai University, Nanjing 211100, China
Abstract:
UPFC(Unified Power Flow Controller) is capable of efficient power flow controls. However, current practical control strategies are limited to the control station level. The dynamic optimal power flow with UPFC can effectively improve the security and economic of the power grid, which, however, suffers from the problems of low efficiency and poor convergence, as a result, its real-time applications in practical power grids cannot be satisfied. On this background, a linear dynamic optimal power flow model is proposed, which is insensitive to the initial value and includes four steps of decoupling, substitution, hot start and iteration. A quasi-linearized UPFC model is also studied, based on which a quasi-linearized dynamic optimal power flow model with UPFC is established. Based on the equivalent principle, a 117-bus equivalent Nanjing West Ring Network is derived from the regional power grid, and the simplified primal-dual interior point method is employed to solve the optimization problem. Test results show that the proposed model exhibits satisfactory computational efficiency and calculation accuracy.
Key words:  unified power flow controller  dynamic optimal power flow  quasi-linearized  equivalent system

用微信扫一扫