引用本文:贾科,李俊涛,陈金锋,杨彬,毕天姝.多端口分布式光伏接入直流配电系统整体故障穿越协调控制[J].电力自动化设备,2021,41(5):
JIA Ke,LI Juntao,CHEN Jinfeng,YANG Bin,BI Tianshu.Integrated fault ride through control for multi-port DC distribution system with distributed photovoltaic generation[J].Electric Power Automation Equipment,2021,41(5):
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 4015次   下载 2279  
多端口分布式光伏接入直流配电系统整体故障穿越协调控制
贾科, 李俊涛, 陈金锋, 杨彬, 毕天姝
华北电力大学 新能源电力系统国家重点实验室,北京 102206
摘要:
因新能源渗透率高,多端口光伏分布式接入直流配电系统在并网换流器交流送出线路发生故障时应具备故障穿越的能力。然而,并网换流器与光伏直流变压器的容量、控制方式不同,即使两者在故障穿越期间可以相互高速通信协调,但是由于不同换流设备功率调节响应存在差异,直流母线电压容易发生较大波动,进而导致整个系统脱网。为此,提出了基于光伏端口电压调节的变功率控制方式,对直流配电系统有功功率进行动态补偿,可使直流母线电压快速恢复至额定运行点,解决交流故障导致的直流母线电压大范围波动问题,并给出了调节系数的整定与电压触发阈值的选取方式,从而实现可靠的故障穿越。PSCAD仿真结果表明,与传统控制策略相比,所提方法在不同故障程度、系统在交流故障前运行在不同有功功率的情况下,光伏电站均能有效且快速调节有功功率,避免了直流配电系统中换流器闭锁,保障了并网换流器故障穿越的实现。
关键词:  多端口  分布式光伏  直流配电系统  故障穿越  变功率控制
DOI:10.16081/j.epae.202105032
分类号:TM721
基金项目:国家重点研发计划项目(2018YFB0904104);国家电网公司科技项目(SGHB0000KXJS1800685)
Integrated fault ride through control for multi-port DC distribution system with distributed photovoltaic generation
JIA Ke, LI Juntao, CHEN Jinfeng, YANG Bin, BI Tianshu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
Abstract:
Due to the high penetration of renewable energy, multi-port DC distribution system with distributed photovoltaic generation should have the ability of fault ride through when the AC lines of the grid connected converter fail. However, the grid connected converter and photovoltaic DC transformer are different in capa-city and control mode. Even if they can communicate and coordinate with each other at high speed during fault ride through period, due to the difference of power regulation response of different converters, the DC bus voltage is prone to large fluctuation, and then cause the whole system trip-off from grid. Therefore, a variable power control method based on the regulation of photovolatic array port voltage is proposed, which can dynamically compensate the active power of the DC distribution system. The DC bus voltage can be quickly recovered to the rated operating point, and the wide-range fluctuation of DC bus voltage caused by AC fault is solved. The setting principle of adjustment coefficient and the selection of voltage threshold are given to realize reliable fault ride through. Results of PSCAD simulation show that compared with the traditional control strategy, the proposed method can effectively and quickly adjust the active power of photovolatic station under different fault levels and different active power before AC fault occurs, thus avoi-ding converter blocking in DC distribution system and ensuring the realization of fault ride through of the grid connected converter.
Key words:  multi-port  distributed photovoltaic generation  DC distribution system  fault ride through  variable power control