摘要:
根据复杂同塔线路的结构特点和保护分析要求,以PSCAD为核心,提出了一种适用于复杂同塔结构的线路仿真模型构建方法。基于MATLAB环境建立专用软件模块,实现故障条件自动切换及PSCAD软件的循环调度控制。对仿真数据预处理和保护功能模块进行了设计。基于上述工作,开发了一套复杂同塔线路保护动作特性分析软件。工程应用实例验证了该软件的有效性和正确性。
关键词:  同塔线路  继电保护  动作特性  软件设计  仿真  故障分析
DOI:
分类号:
基金项目:广东电网公司电力科学研究院合作项目(ztgh-201301- 001)
Design and development of operational characteristics simulation & analysis software for relay protections of complex transmission lines on same tower
AN Ranran1, HE Maohui2, WANG Yi1, ZHANG Zhe2, HU Yulan1, TANG Cui2, LONG Mao2
1.Guangdong Provincial Key Laboratory of Smart Grid Technology,Electric Power Research Institute of Guangdong Power Grid Corporation,Guangzhou 510080,China;2.State Key Laboratory of Advanced Electromagnetic Engineering and Technology,Huazhong University of Science and Technology,Wuhan 430074,China
Abstract:
Based on the structural characteristics of complex transmission lines on same tower and according to the demands of protective analysis,a suitable construction method of line simulation model with PSCAD as its core is proposed. The special software modules are established in the MATLAB environment to realize the automatic switching among different fault conditions and the control of PSCAD loop schedule while the preprocessing module of simulation data and the protective functional modules are designed,based on which,the operational characteristics simulation and analysis software for the relay protections of complex transmission lines on same tower is developed. Its validity and correctness are verified by the engineering applications.
Key words:  transmission lines on same tower  relay protection  operational characteristics  software design  computer simulation  failure analysis