双馈抽水蓄能机组用中点箝位式三电平变流器损耗与结温分布
李辉1, 宋二兵1, 刘海涛1, 白鹏飞1, 黄樟坚1, 骆林2, 黄智欣2
1.重庆大学 输配电装备及系统安全与新技术国家重点实验室,重庆400044;2.东方电气集团东方电机有限公司,四川德阳618000
摘要:
针对双馈抽水蓄能机组(DFPSU)运行工况转换频繁,分析不同运行工况下中点箝位式(NPC)三电平变流器功率器件损耗及结温分布。基于DFPSU运行特点,以机侧变流器单相桥臂功率模块为例,研究了不同运行工况下各个功率器件开关动作和电流通路,理论上分析了器件损耗分布不均现象;基于功率器件导通损耗和开关损耗计算模型,建立其热网络等效电路和结温计算模型,考虑DFPSU控制策略,并基于PLECS平台建立了NPC三电平变流器功率器件电热耦合仿真模型;对机组在发电、电动和调相运行工况下的器件损耗和结温分布进行仿真。理论分析与仿真结果表明,不同运行工况下器件损耗不同,变流器中间位置的主开关和箝位二极管的损耗和平均结温最大,且机组在同步转速点附近器件结温波动最大。
关键词:  双馈抽水蓄能机组  NPC三电平变流器  损耗  结温分布  运行工况
DOI:10.16081/j.issn.1006-6047.2018.02.007
分类号:TM346;TM46
基金项目:国家自然科学基金资助项目(51377184,51675354)
Loss and junction temperature distribution of NPC three-level converter in doubly-fed pumped storage unit
LI Hui1, SONG Erbing1, LIU Haitao1, BAI Pengfei1, HUANG Zhangjian1, LUO Lin2, HUANG Zhixin2
1.State Key Laboratory of Power Transmission Equipment and System Security & New Technology, Chongqing University, Chongqing 400044, China;2.Dongfang Electric Machinery Co.,Ltd., Deyang 618000, China
Abstract:
In view of the frequent conversion of DFPSU(Doubly-Fed Pumped Storage Unit) operating condition, the loss and junction temperature distribution of NPC(Neutral Point Clamped) three-level converter under different operating conditions are analyzed. Based on operating characteristics of DFPSU, power module of single-phase bridge arm in rotor converter is taken as an example, where the switch motion and current path of power device under different operating conditions are illustrated, and the unequal loss distribution phenomenon of power device is analyzed theoretically. Then, the equivalent circuit of thermal network and the calculation model of junction temperature are proposed according to the calculation model of conduction and switching loss. The electrothermal coupling model of NPC three-level converter is established on PLECS platform, in which the loss and junction temperature of power device are simulated under the operating conditions of generation, motor and phase modulation. The theoretical analysis and simulative results indicate that the device loss varies with operating conditions of pumped storage system, and the most dangerous devices in NPC three-level converter are the middle switch and clamp diode. In addition, the biggest junction temperature fluctuation of power device occurs near the synchronous speed.
Key words:  doubly-fed pumped storage unit  NPC three-level converter  losses  junction temperature distribution  operating condition