引用本文:华铤,林桦,肖建杰,王兴伟.一种扩展LCL型并网逆变器有效阻尼区的超前补偿方法[J].电力自动化设备,2020,40(9):
HUA Ting,LIN Hua,XIAO Jianjie,WANG Xingwei.Lead compensation method for extending valid damping region of LCL-type grid-connected inverter[J].Electric Power Automation Equipment,2020,40(9):
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 5455次   下载 2000  
一种扩展LCL型并网逆变器有效阻尼区的超前补偿方法
华铤, 林桦, 肖建杰, 王兴伟
华中科技大学 电气与电子工程学院 电力电子与能量管理教育部重点实验室,湖北 武汉 430074
摘要:
考虑数字控制延迟,LCL型并网逆变器系统的有效阻尼区仅在采样频率 fs 的1/ 6以内,较窄的阻尼区间使得系统的稳定区域很小,不利于系统参数的设计。针对此问题,提出一种在阻尼环路中加入超前补偿控制器的改进方法。首先,通过分析系统的有源阻尼特性,得出加入超前补偿后系统的有效阻尼区可以扩展到(0, fR),其中fR∈(fs / 6, fs / 3)。接着分析了加入超前补偿后被控对象的稳定性,给出临界电容电流反馈系数与超前补偿参数之间的关系。为了扩大原系统的稳定区域,提出了一套超前补偿控制器的参数设计方法。最后通过实验进行验证,实验结果验证了所提方法的有效性。
关键词:  LCL型并网逆变器  电容电流反馈  控制延迟  有效阻尼区  稳定区域  补偿
DOI:10.16081/j.epae.202009002
分类号:TM464
基金项目:
Lead compensation method for extending valid damping region of LCL-type grid-connected inverter
HUA Ting, LIN Hua, XIAO Jianjie, WANG Xingwei
Key Laboratory of Power Electronics and Energy Management, Ministry of Education, School of Electrical and Electronic Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
Abstract:
Considering the digital control delay, the valid damping region of LCL-type grid-connected inverter system is only within 1/6 sampling frequency( fs / 6). The narrow damping region results in the small stability region of system, which is not conducive to the design of system parameters. To solve this problem, an improved method of adding a lead compensator in the damping loop is proposed. Firstly, by analyzing the active damping characteristics of system, it is concluded that the effective damping region of system after adding lead compensation can be extended to (0, fR),where fR ∈( fs / 6, fs / 3). Then, the stability of the controlled object after adding lead compensation is analyzed, and the relationship between the critical capacitor current feedback coefficient and the parameters of lead compensation is given. In order to extend the stability region of the original system, a set of parameter design method of the lead compensator is proposed. Finally, the experimental results verify the effectiveness of the proposed method.
Key words:  LCL-type grid-connected inverter  capacitor-current-feedback  control delay  valid damping region  stability region  compensation

用微信扫一扫

用微信扫一扫