引用本文: | 任震,欧开健,荆勇.直流输电系统换相失败的研究(二)--避免换相失败的措施[J].电力自动化设备,2003,(6):6-9 |
| .Research on commutation failure in HVDC transmission system Part 2 :Measures against commutation failure[J].Electric Power Automation Equipment,2003,(6):6-9 |
|
|
摘要: |
对影响换相失败的一些直流输电系统参数进行了灵敏度分析,进一步揭示各参数与换相失败的关系。结合论文第一部分中的分析及灵敏度分析,提出了一些避免换相失败的措施,包括换相失败的预防措施和防止继发性换相失败的措施两类。 |
关键词: 直流输电 逆变器 换相失败 措施 |
DOI: |
分类号:TM721.1 TM711 |
基金项目: |
|
Research on commutation failure in HVDC transmission system Part 2 :Measures against commutation failure |
REN Zhen 1 OU Kai-jian 1 JING Yong 2
|
Abstract: |
The sensitivities of the parameters that affect commutation failure in HVDC system are analyzed and the relations between them are discovered.Based on the sensitivity analysis and the analysis in Part one,the measures against commutation failure are given,including the preventive measures and the measures against followed commutation failure. |