引用本文: | 朱连成,肖阳,金石,陈晓红.开绕组无刷双馈风力发电机直接功率控制容错策略[J].电力自动化设备,2024,44(5):73-78,87. |
| ZHU Liancheng,XIAO Yang,JIN Shi,CHEN Xiaohong.Direct power control strategy with fault-tolerant for open-winding brushless doubly-fed wind power generator[J].Electric Power Automation Equipment,2024,44(5):73-78,87. |
|
摘要: |
针对无刷双馈发电机提出了一种控制绕组采用开绕组拓扑(OW-BDFG)的馈电方案,将三相控制绕组两端打开分别连接变流器构成双两电平变流器(D-TLCs)馈电拓扑,对机侧变流器功率器件IGBT因故障切除后的容错控制策略进行深入分析,提出了功率偏差比较直接功率控制(PEC-DPC)的D-TLCs电压空间矢量优化方案。对比分析了8/4极25 kW样机的仿真及实验结果,表明:当机侧变流器1个或2个IGBT被切除后,所提OW-BDFG的PEC-DPC仍可实现变速恒频、最大功率点跟踪及单位功率因数控制,进一步提高了该发电机系统的可靠性和鲁棒性。 |
关键词: 无刷双馈发电机 开绕组 双两电平变流器 直接功率控制 容错控制 最大功率点跟踪 |
DOI:10.16081/j.epae.202312035 |
分类号: |
基金项目:国家自然科学基金资助项目(51537007);辽宁省教育厅面上项目(LJKZ0617) |
|
Direct power control strategy with fault-tolerant for open-winding brushless doubly-fed wind power generator |
ZHU Liancheng1, XIAO Yang1, JIN Shi2, CHEN Xiaohong1
|
1.School of Electrical Engineering, Liaoning University of Technology, Jinzhou 121001, China;2.School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
|
Abstract: |
A novel open-winding brushless doubly-fed generator(OW-BDFG) topology is proposed, the two ends of three-phase control windings are opened and respectively connected to the converter to form dual two-level converters(D-TLCs) feed topology. The fault-tolerant control strategy of D-TLCs with insulated gate bipolar transistor(IGBT) removed due to some faults is deeply analyzed, and the voltage space vector optimization scheme of D-TLCs for power error comparison direct power control(PEC-DPC) is presented. Simulative analysis and experimental verification of the 8/4-pole 25 kW prototype show that the variable speed constant frequency, maximum power point tracking and unit power factor control of the proposed PEC-DPC for the OW-BDFG can still be achieved after removing 1 or 2 IGBTs, which improves the reliability and robustness of the OW-BDFG system. |
Key words: brushless doubly-fed generator open-winding dual two-level converters direct power control fault-tolerant control maximum power point tracking |